Wood, MDF, fabric, acrylic: which materials you can use in your stand, what fire reaction classes mean and which certificates you must have with you at the show.
Even before choosing colours, anyone building a stand must answer a less creative and far more important question: are the materials I am using permitted? Italian exhibition centres are places with many people in enclosed spaces, which is why they require materials with a good fire reaction class, with the relevant certificates.
In this guide we explain simply what fire reaction classes are, how the most common materials behave, which documents are needed, how fire-retardant treatment works and what inspectors check at shows. To understand how this affects choices and costs, also read our guides to wooden and MDF stands, cardboard stands and the cost of an exhibition stand.
In short: fire reaction measures how a material behaves when it catches fire. Venues generally require certified materials (often Italian class 1 or Euroclass B-s1,d0 or equivalent, to be checked in the show’s technical regulations) and documents to be kept on the stand. Wood, MDF and fabrics can be fine if treated or certified; every material must be checked before buying.
Common materials and fire reaction
| 📌 Material | 🔥 Typical behaviour | ✅ What to do | 📄 Document |
|---|---|---|---|
| 🪵Solid wood and plywood | Combustible, must be treated | Fire-retardant treatment with certified product | Treatment certificate |
| 🧱MDF and fibreboard | Combustible; fire-retardant versions exist | Use fire-retardant MDF or treat | Data sheet or certificate |
| 🧵Fabrics for walls and graphics | Variable: fire-retardant fabrics needed | Choose certified fabric | Fire reaction certificate |
| 🔷Acrylic (PMMA) | Unsuitable for large surfaces | Use certified versions or polycarbonate | Data sheet |
| 📦Cardboard and paper materials | Combustible, often restricted | Check the regulations, treat | Fire-retardant treatment certificate |
| 🌿Carpet and flooring | Must meet the required class | Use fire-retardant carpet | Class certificate |
1. What fire reaction class is and why it matters
Fire reaction describes how a material behaves when it catches fire: whether it ignites easily, how much it spreads fire, how much smoke and what flaming droplets it produces. It doesn’t measure how much it resists fire, but how much it feeds it. Materials are divided into classes: in the traditional Italian system there are classes 0, 1, 2 and so on; in the European system, the Euroclasses (from A1 to F, with subclasses s for smoke and d for droplets).
A hall holds thousands of people and many fit-outs made with different materials. That is why venues impose rules on materials and state the minimum permitted class in the technical regulations, which differ from venue to venue and show to show: they must always be read before buying.
2. Fire-retardant treatment: how it works
Fire-retardant treatment is a treatment (paint, impregnating agent, spray) that improves the fire behaviour of wood and fabrics. To be valid, the product must be certified, applied according to the instructions and documented with a declaration from the applicator.
It must be done before the show, in the workshop, not at the venue. If the material is cut or painted afterwards, the treatment may no longer be valid: it is best to plan the steps in advance.
3. How a material is tested
A material’s class is determined by laboratory tests according to technical standards: a small sample is exposed to a flame under controlled conditions and flame spread, smoke and droplets are measured. The laboratory issues a test report, from which the classification derives.
For you, in practice, it is enough to know that whoever sells the material must be able to provide the documentation: data sheet, certificate or declaration of conformity. Without documents, the material cannot be shown to comply.
4. Certificates and declarations you need
Every stand has a document folder. It usually contains the fire reaction certificates for the materials, the declaration of conformity for the electrical system, the declaration of correct installation and, for complex structures, calculations and design.
The folder must be kept on the stand for the whole show, because inspections can come at any time. An experienced stand builder prepares it in advance and gives you a copy: always ask for it.
5. The most commonly used stand materials
Wood and its derivatives, such as MDF, are combustible: at shows they are used treated with certified fire retardant or in fire-retardant versions. Fabrics for walls and graphics must be certified fire-retardant. Standard acrylic should be used with caution and on small surfaces; for large surfaces, certified versions or polycarbonate are chosen.
Carpet, flooring, PVC structures and packaging must also be checked. For specific cases, see our guides to wooden and MDF stands, backlit fabric walls and acrylic displays.
6. Extinguishers, exits and escape routes
Besides materials, the venue checks safety around the stand: accessible extinguishers, visible signage, free exits and escape routes. Never cover columns with extinguishers, emergency signs or hydrants with panels or graphics.
In the stand design, the distances required by the regulations are left clear and an extinguisher is provided where mandatory. An experienced designer checks these points from the rendering stage.
7. A properly installed electrical system
The stand’s electrical system is one of the most common causes of problems at shows. It must be installed by a qualified electrician, with suitable materials and residual current protection, and certified with a declaration of conformity.
LED lights, monitors and sockets must be sized to actual consumption, with tidy cables and an accessible distribution board. The connection to the venue is booked in advance and has its own costs.
8. Inspections at the show: what they check
Before and during the show, the venue may ask for documentation and check materials, exits, extinguishers and the electrical system. Those who do not comply may have to modify or remove stand elements, even while the show is open.
To avoid problems, submit the documents within the deadlines set by the venue, keep a copy on the stand and entrust the technical part to people who do it every day. For a reference on installation times, read our guide to stand build-up and dismantling.
How to choose the right materials
Start from your show’s regulations and the documentation required: the materials follow.
| 🎯 Need | ✅ Solution | 💡 Note |
|---|---|---|
| 📘Understanding what is allowed | Read the venue’s technical regulations | Changes from show to show |
| 🪵Stand with wood and MDF | Fire-retardant panels or certified treatment | Treat before cutting and painting |
| 🧵Fabric walls and graphics | Fire-retardant fabric with certificate | Ask the supplier for the certificate |
| 🔷Acrylic surfaces | Certified version or polycarbonate | Limit large surfaces |
| 📄Documents to keep on the stand | Folder with certificates and declarations | Keep it for the whole show |
| 🔌Electrical system | Installed and certified by a qualified electrician | With declaration of conformity |
What to prepare before choosing materials
- Technical regulations of the venue and show, updated to the current year.
- List of planned materials: walls, floors, graphics, furniture.
- Data sheets and certificates requested from suppliers.
- Fire-retardant treatments to be carried out and time to do them in the workshop.
- Documentation to be submitted to the venue and kept on the stand.
If you want to entrust everything to people who deal with it every day, see how a turnkey stand works and how to choose a stand builder.
Italian and European classes: how to read them
Italian show regulations still use two classification systems. The traditional Italian system uses classes from 0 (non-combustible material) to 5, and for fit-outs usually requires class 1 or better. The European system, based on EN 13501-1, uses the Euroclasses from A1 to F, with two additional indicators: “s” for smoke production (from s1, little smoke, to s3) and “d” for flaming droplets or particles (from d0, no droplets, to d2).
| 🔥 Euroclass | 📖 Meaning in brief | 🧱 Typical examples |
|---|---|---|
| 🪨A1 / A2 | Non-combustible or nearly so | Metals, glass, stone, special plasterboard |
| 🟢B | Very limited contribution to fire | Certified fire-retardant MDF and plywood |
| 🟡C | Limited contribution | Some treated panels and laminates |
| 🟠D | Medium contribution | Untreated wood and MDF of good thickness |
| 🔴E / F | High contribution or not classified | Materials unsuitable for fit-outs |
For stand walls, many shows require a class equivalent to B-s2,d0 or Italian class 1; for floors there are specific classes with the suffix “fl” (for example Bfl-s1). The exact requirements change from venue to venue and are always stated in the technical regulations, which must be read before choosing materials.
An example: documentation for a 48 m² stand
For a 48 m² custom stand with lacquered MDF walls, a tension fabric ceiling, carpet, a solid surface counter and curtains for the meeting room, the stand builder prepares a file containing: classification certificates for fire-retardant MDF, fabric, carpet and curtains, issued by the manufacturers; declarations of conformity linking those certificates to the materials actually used on the stand; a declaration of correct installation, because a certified material loses its class if it is installed differently from how it was tested; and the declaration of conformity for the electrical system.
The file is uploaded to the show portal before build-up and a printed copy stays on the stand for the entire event. In the event of an inspection by the fire brigade or show technicians, the documents are immediately available. Without this documentation, the stand can be stopped or, in the most serious cases, have to remove non-certified materials.
Paints, graphics and added materials
An often overlooked point concerns what is added to certified materials. A paint applied to a fire-retardant panel can change its fire behaviour if it is not itself suitable; the same goes for adhesive films, wallpaper, decorations and props. That is why it is best to use paints and prints with compatible certifications, ask the graphics supplier for the classification of print materials and limit flammable decorations such as dried flowers, paper, untreated fabrics and expanded plastic objects. Real plants too, if abundant, should be assessed against the show’s regulations.
The most common mistakes
- Mismatched certificates: the certificate must refer exactly to the material and thickness used.
- DIY fire-proofing: spraying a product on a fabric doesn’t make it certified without a valid treatment declaration.
- Documents left at the office: certificates must be on the stand, not just on the computer.
- Materials brought by the exhibitor: curtains, rugs and decorations added at the last minute must follow the same rules.
- Hidden extinguishers: they must remain visible and accessible, not covered by furniture or graphics.
Frequently asked questions
Quick answers to the questions we hear most often
Are the rules the same at shows abroad?
The principles are similar, but each country has its own requirements and documents: in Germany, for example, reference is made to the DIN 4102 (B1) classification as well as the Euroclasses. Always check the local regulations.
Does a fire reaction certificate expire?
The material certificate remains valid, but fire-retardant treatments applied to fabrics can lose effectiveness with washing: in that case the treatment must be renewed and documented.
What is the fire reaction class?
It is the classification that indicates how much a material contributes to the spread of a fire. It is determined by laboratory tests and declared with a certificate or data sheet.
What class is required for a stand?
It depends on the venue and the show: many regulations require class 1 or equivalent Euroclass materials. It must always be checked in the current technical regulations.
Can wood be used on a stand?
Yes, if treated with certified fire retardant or in a fire-retardant version, with the documentation required by the venue.
Is a certificate needed for fabrics?
Yes: fabric walls and graphics must be fire-retardant and certified. Ask the supplier for the certificate before ordering.
Do you handle the documents?
Yes: we choose compliant materials and prepare certificates and declarations, to be submitted to the venue and kept on the stand.
Want a stand that complies with venue rules?
We design and build stands with certified materials and complete documentation, with installation and lighting, in Italy and across Europe.